ISO 5211 Flange Sizes & Torque Limits
Flange designations, pitch circle diameters and maximum transmissible torque.
Updated
- ISO 5211
- mounting
- flange
- PCD
ISO 5211 standardises the mounting interface between part-turn actuators and valves. Each flange designation defines a pitch circle diameter (PCD) and a maximum torque the joint is designed to transmit.
| Flange | PCD (mm) | Max torque (Nm) |
|---|---|---|
| F05 | 50 | 125 |
| F07 | 70 | 250 |
| F10 | 102 | 500 |
| F12 | 125 | 1,000 |
| F14 | 140 | 2,000 |
| F16 | 165 | 4,000 |
| F25 | 254 | 8,000 |
| F30 | 298 | 16,000 |
| F35 | 356 | 32,000 |
| F40 | 406 | 63,000 |
| F48 | 483 | 125,000 |
| F60 | 603 | 250,000 |
See Sizing a Quarter-Turn Actuator to a Valve for the full sizing check and NAMUR / VDI/VDE 3845 Accessory Interfaces for accessory interfaces.