Skip to content
Vectis Controls

ISO 5211 Flange Sizes & Torque Limits

Flange designations, pitch circle diameters and maximum transmissible torque.

Updated

  • ISO 5211
  • mounting
  • flange
  • PCD

ISO 5211 standardises the mounting interface between part-turn actuators and valves. Each flange designation defines a pitch circle diameter (PCD) and a maximum torque the joint is designed to transmit.

FlangePCD (mm)Max torque (Nm)
F0550125
F0770250
F10102500
F121251,000
F141402,000
F161654,000
F252548,000
F3029816,000
F3535632,000
F4040663,000
F48483125,000
F60603250,000

See Sizing a Quarter-Turn Actuator to a Valve for the full sizing check and NAMUR / VDI/VDE 3845 Accessory Interfaces for accessory interfaces.