Skip to content
Vectis Controls

ESD vs HIPPS vs SSIV

Three shutdown functions that are often confused, and what each demands from the valve package.

Updated

  • ESD
  • HIPPS
  • SSIV
  • SIL
FunctionPurposeTypical drivers
ESDIsolate inventory on an emergency shutdown signalFail-safe, reliable stroke, defined closure time
HIPPSProtect downstream equipment from overpressure instead of reliefHigh SIL, very fast closure, redundancy
SSIVIsolate a subsea pipeline from the topside inventoryRemote location, hydraulic actuation, long accumulator duty

The safety requirements specification (SRS) sets the required SIL, process safety time and allowable leakage for each function. The valve package: valve, actuator, solenoids and logic, must be engineered as a whole to meet it.

Diagnostic techniques such as Partial Stroke Testing (PST) can extend proof test intervals, and sensing pilots on API 6A wellhead valves provide self-contained high/low pressure trips without a control system.

Connected articles