Sizing a Hydraulic Accumulator

Gas laws, pre-charge pressure and the usable volume you actually get.

Updated

  • accumulator
  • hydraulics
  • pre-charge

Self-contained hydraulic actuators and wellhead control panels rely on accumulators for stored energy. The usable fluid volume between maximum and minimum system pressure is much smaller than the accumulator nominal size.

V0=ΔV(P0P1)1/n−(P0P2)1/nV_0 = \frac{\Delta V}{\left(\frac{P_0}{P_1}\right)^{1/n} - \left(\frac{P_0}{P_2}\right)^{1/n}}
V0V_0 nominal gas volume · ΔV\Delta V required fluid · P0P_0 pre-charge · P1P_1 min · P2P_2 max (absolute) · n=1n = 1 isothermal, ≈1.4\approx 1.4 adiabatic.
  • Set pre-charge around 90% of minimum working pressure for bladder accumulators.
  • Use n ≈ 1.4 for fast discharge (ESD strokes). It gives a larger, safer accumulator.
  • Correct pre-charge for ambient temperature at the time of charging.